Select SWG or AWG before looking up a wire diameter. The calculator uses the corresponding diameter and chosen metal density to estimate cross-sectional area and mass per metre. Use a measured diameter or the wire maker’s drawing when trade gauge descriptions on the purchase order are ambiguous.
Pick the gauge system and number to get the wire diameter, its cross-section area and the weight per metre of round wire in the material you choose. SWG diameters come from the cited historical handbooks. AWG diameters are calculated from the geometric progression described in the National Bureau of Standards handbook.
Calculator
Enter your values and press Calculate. The result appears here.
Formula
AWG: d (in) = 0.005 × 92^((36 − n) ÷ 39), with n = 0 for 0 (1/0), −1 for 00, −2 for 000, −3 for 0000SWG: d (in) from the cited table; d (mm) = d (in) × 25.4Area = π/4 × d²; kg/m = area (mm²) × density (g/cm³) ÷ 1,000
Worked example
12 AWG: 0.005 × 92^(24/39) = 0.0808 in = 2.053 mm, area 3.309 mm². In SS 304 it weighs 26.2 g per metre.
| AWG | Diameter (in) | Diameter (mm) | Area (mm²) |
|---|---|---|---|
| 0000 | 0.4600 | 11.684 | 107.219 |
| 000 | 0.4096 | 10.405 | 85.029 |
| 00 | 0.3648 | 9.266 | 67.431 |
| 0 | 0.3249 | 8.251 | 53.475 |
| 1 | 0.2893 | 7.348 | 42.408 |
| 2 | 0.2576 | 6.544 | 33.631 |
| 3 | 0.2294 | 5.827 | 26.670 |
| 4 | 0.2043 | 5.189 | 21.151 |
| 5 | 0.1819 | 4.621 | 16.773 |
| 6 | 0.1620 | 4.115 | 13.302 |
| 7 | 0.1443 | 3.665 | 10.549 |
| 8 | 0.1285 | 3.264 | 8.366 |
| 9 | 0.1144 | 2.906 | 6.634 |
| 10 | 0.1019 | 2.588 | 5.261 |
| 11 | 0.0907 | 2.305 | 4.172 |
| 12 | 0.0808 | 2.053 | 3.309 |
| 13 | 0.0720 | 1.828 | 2.624 |
| 14 | 0.0641 | 1.628 | 2.081 |
| 15 | 0.0571 | 1.450 | 1.650 |
| 16 | 0.0508 | 1.291 | 1.309 |
| 17 | 0.0453 | 1.150 | 1.038 |
| 18 | 0.0403 | 1.024 | 0.823 |
| 19 | 0.0359 | 0.912 | 0.653 |
| 20 | 0.0320 | 0.812 | 0.518 |
| 21 | 0.0285 | 0.723 | 0.410 |
| 22 | 0.0253 | 0.644 | 0.326 |
| 23 | 0.0226 | 0.573 | 0.258 |
| 24 | 0.0201 | 0.511 | 0.205 |
| 25 | 0.0179 | 0.455 | 0.162 |
| 26 | 0.0159 | 0.405 | 0.129 |
| 27 | 0.0142 | 0.361 | 0.102 |
| 28 | 0.0126 | 0.321 | 0.081 |
| 29 | 0.0113 | 0.286 | 0.064 |
| 30 | 0.0100 | 0.255 | 0.051 |
| 31 | 0.0089 | 0.227 | 0.040 |
| 32 | 0.0080 | 0.202 | 0.032 |
| 33 | 0.0071 | 0.180 | 0.025 |
| 34 | 0.0063 | 0.160 | 0.020 |
| 35 | 0.0056 | 0.143 | 0.016 |
| 36 | 0.0050 | 0.127 | 0.013 |
| 37 | 0.0045 | 0.113 | 0.010 |
| 38 | 0.0040 | 0.101 | 0.008 |
| 39 | 0.0035 | 0.090 | 0.006 |
| 40 | 0.0031 | 0.080 | 0.005 |
Sources: U.S. National Bureau of Standards, Copper Wire Tables, Handbook 100 · Source register
- Formula
d (in) = 0.005 × 92^((36 − n)/39); mm = in × 25.4- Unit
- inch to 4 decimals, mm and mm² to 3 decimals
- Last verified
The metric diameter and cross-sectional area use the unrounded calculated diameter.
| SWG | Diameter (in) | Diameter (mm) | Area (mm²) | SS 304 (kg/m) |
|---|---|---|---|---|
| 1 | 0.3000 | 7.620 | 45.604 | 0.3616 |
| 2 | 0.2760 | 7.010 | 38.595 | 0.3061 |
| 3 | 0.2520 | 6.401 | 32.180 | 0.2552 |
| 4 | 0.2320 | 5.893 | 27.275 | 0.2163 |
| 5 | 0.2120 | 5.385 | 22.775 | 0.1806 |
| 6 | 0.1920 | 4.877 | 18.681 | 0.1481 |
| 7 | 0.1760 | 4.470 | 15.693 | 0.1244 |
| 8 | 0.1600 | 4.064 | 12.972 | 0.1029 |
| 9 | 0.1440 | 3.658 | 10.509 | 0.0833 |
| 10 | 0.1280 | 3.251 | 8.301 | 0.0658 |
| 11 | 0.1160 | 2.946 | 6.816 | 0.0541 |
| 12 | 0.1040 | 2.642 | 5.482 | 0.0435 |
| 13 | 0.0920 | 2.337 | 4.290 | 0.0340 |
| 14 | 0.0800 | 2.032 | 3.243 | 0.0257 |
| 15 | 0.0720 | 1.829 | 2.627 | 0.0208 |
| 16 | 0.0640 | 1.626 | 2.076 | 0.0165 |
| 17 | 0.0560 | 1.422 | 1.588 | 0.0126 |
| 18 | 0.0480 | 1.219 | 1.167 | 0.0093 |
| 19 | 0.0400 | 1.016 | 0.811 | 0.0064 |
| 20 | 0.0360 | 0.914 | 0.656 | 0.0052 |
| 21 | 0.0320 | 0.813 | 0.519 | 0.0041 |
| 22 | 0.0280 | 0.711 | 0.397 | 0.0031 |
| 23 | 0.0240 | 0.610 | 0.292 | 0.0023 |
| 24 | 0.0220 | 0.559 | 0.245 | 0.0019 |
| 25 | 0.0200 | 0.508 | 0.203 | 0.0016 |
| 26 | 0.0180 | 0.457 | 0.164 | 0.0013 |
| 27 | 0.0164 | 0.417 | 0.137 | 0.0011 |
| 28 | 0.0148 | 0.376 | 0.111 | 0.0009 |
| 29 | 0.0136 | 0.345 | 0.093 | 0.0007 |
| 30 | 0.0124 | 0.315 | 0.078 | 0.0006 |
Sources: Kent (1907), p. 28 and Foster (1918), p. 141 · Source register
- Formula
mm = in × 25.4 (3 decimals); kg/m = π/4 × d² × density ÷ 1,000- Density
- SS 304 / 304L: 7.93 g/cm³ (typical value from the source)
- Unit
- inch 4 decimals, mm 3 decimals
- Last verified
Same SWG data as the sheet metal gauge chart (Kent 1907 and Foster 1918, matched in both).
Download the reference PDF
Gauge reference: AWG and SWG wire, SS sheet weight by thickness. The PDF holds the same tables as the pages, generated from the same data, with the verification date in the footer.
Sources and last verified
- U.S. National Bureau of Standards, Copper Wire Tables, Handbook 100, American Wire Gage
- ASTM B258 publisher reference for nominal AWG sizes
- William Kent, The Mechanical Engineer’s Pocket-book (1907), p. 28
- Horatio A. Foster, Electrical Engineer’s Pocket-book (1918), p. 141
- SS 304 / 304L density 7.93 g/cm³: Nippon Steel Stainless Steel catalogue S008, austenitic physical-property table pp. 4-5 and mass table pp. 20-21 (SUS304: 7.93)
Last verified: . Verify against the applicable standard and edition named in your purchase order.
Common questions
What is 16 SWG in mm?
16 SWG is 0.064 in = 1.626 mm.
What is 12 AWG in mm?
12 AWG is 0.0808 in = 2.053 mm (from the AWG formula).
Are SWG and AWG the same?
No. 16 SWG is 1.626 mm but 16 AWG is 1.291 mm. Check which system a drawing or catalogue uses.
Is gauge the same as the diameter of a cable bundle?
The chart describes the selected wire gauge. A finished cable includes construction and insulation that change its outside diameter.
Does changing the material change the gauge diameter?
The gauge system sets the listed wire diameter. Material density affects the calculated mass for that diameter.
Published by Steel Impex India · Technical reference policy